Purchase Premium Quality Gamma Solar in Bangladesh

Gamma Solar PCU

The Gamma solar PCU (Power Conditioning Unit) is rMPPT offline solar PCU one phase in one phase out. It is very affordable for schools, hospitals, petrol pumps, industries, and buildinds and also for home. The Gamma Solar PCU (rMPPT) is uses the solar power energy in first priority and the government electricity (grid) in second priority to charge the solar batteries.

Usage of power energy from grid is secondary, grid power is only used when solar energy is not present and solar battery voltage level reduces to a certain level. Grid power is also needed when solar power is reduced to a certain level and battery voltage is reduced to a certain level.

Gamma solar PCU has the advance features like DSP base design built in MPPT solar charge controller, most advanced LCD features, maximum preference to solar power, smart PCU, capability of 100% solar panel rating, compatible with all PV arrays having different no. of cells (36 cell/60 cell/72 cell), lightning protection, high efficiency MPPT inverter.

This is available in various models range like Gamma solar PCU 2kVA/24V, Gamma PCU 2kVA/48V, Gamma solar PCU 3kVA/48V, Gamma PCU 5kVA/48V and Gamma solar PCU 5kVA/96V.

PCU Mode Priority – Solar/Battery/Grid

Hybrid Mode Priority – For Load – Grid/Solar/Battery for Charging – Solar/Grid

Smart Mode Priority – For Day Time – Solar/Battery/Grid for Night Time – Grid/Battery

Price of Gamma PCU

GAMMA PCU
GAMMA PCU
ModelsMRP ( Inclusive of all Taxes )Discounted Price ( Inclusive of all Taxes )
Gamma 2KVA 24V
Gamma 2KVA 48V
Gamma 3KVA 48V
Gamma 5KVA 48V
Gamma 5KVA 96V

Technical Specifications of Gamma PCU 1PH in 1PH out

2KVA 24V Gamma PCU

DescriptionParticulars
Solar PCU Capacity2KVA 24V
Input Voltage Range (min-max)45-90 VDC
Maximum PV Power Recommended2KW
Types of ChargerPWM with MPPT
Charge Controller Peak Efficiency95%
Battery Low Buzzer10.2V
Battery Low Cut10.0V
Battery High Cut15.5V
Battery Charging Voltage by SPV14.5V
Battery Charging Current by SPV18A
Battery Charging Voltage by GRID14.2V
Battery Charging Current by GRID10A
Grid Low Cut Voltage ( IT Load Disable/Enable)120/175V
Grid High Cut Voltage ( IT Load Disable/Enable)280/255V
Inverter Nominal Output Voltage230VAC
Output Supply Phase1 phase, 3 wire
Output WaveformSine wave
Nominal Frequency50.0 HZ
Load Current6.1 A
Inverter Peak Efficiency>88%
ProtectionsOverload, Battery low, Battery high, Output low, Output high, Output Short Circuit, Overheat, Under Frequency, Over Frequency, Solar panel reverse
Display ParametersBattery Voltage, Charging Current, Discharging Current* Solar Voltage, Solar Current, Instantaneous Power, Grid Voltage, I/P Frequency Output Voltage, Output Load% O/P Frequency Grid, Inverter & SPV Charger Status
SwitchesReset for System ON/OFF, up, Down, Back, Enter (for LCD Configuration)
IndicationsSystem ON, Inv. ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under frequency, Over frequency, (IT Mode, Grid Charging, NLSD, Boost Charging, DG Mode)Enable/Disable*
Max Relative Humidity @25*C (non condensing)95%
Weight30KG
Dimension (L X W X H)457 X 254 X 431 mm
MRP Price ( Inclusive of all Taxes )
Discounted  Price ( Inclusive of all Taxes )

2KVA 48V Gamma PCU

DescriptionParticulars
Solar PCU Capacity2KVA 48V
Input Voltage Range (min-max)80-230 VDC
Maximum PV Power Recommended2KW
Types of ChargerPWM with MPPT
Charge Controller Peak Efficiency95%
Battery Low Buzzer10.2V
Battery Low Cut10.0V
Battery High Cut15.5V
Battery Charging Voltage by SPV14.5V
Battery Charging Current by SPV18A
Battery Charging Voltage by GRID14.2V
Battery Charging Current by GRID10A
Grid Low Cut Voltage ( IT Load Disable/Enable)120/175V
Grid High Cut Voltage ( IT Load Disable/Enable)280/255V
Inverter Nominal Output Voltage230VAC
Output Supply Phase1 phase, 3 wire
Output WaveformSine wave
Nominal Frequency50.0 HZ
Load Current6.1 A
Inverter Peak Efficiency>88%
ProtectionsOverload, Battery low, Battery high, Output low, Output high, Output Short Circuit, Overheat, Under Frequency, Over Frequency, Solar panel reverse
Display ParametersBattery Voltage, Charging Current, Discharging Current* Solar Voltage, Solar Current, Instantaneous Power, Grid Voltage, I/P Frequency Output Voltage, Output Load% O/P Frequency Grid, Inverter & SPV Charger Status
SwitchesReset for System ON/OFF, up, Down, Back, Enter (for LCD Configuration)
IndicationsSystem ON, Inv. ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under frequency, Over frequency, (IT Mode, Grid Charging, NLSD, Boost Charging, DG Mode)Enable/Disable*
Max Relative Humidity @25*C (non condensing)95%
Weight27KG
Dimension (L X W X H)381 X 279 X 355 mm
MRP ( Inclusive of all Taxes )
Discounted Price ( Inclusive of all Taxes )

 

3KVA 48V Gamma PCU

 

DescriptionParticulars
Solar PCU Capacity3KVA 48V
Input Voltage Range (min-max)80-230 VDC
Maximum PV Power Recommended3KW
Types of ChargerPWM with MPPT
Charge Controller Peak Efficiency95%
Battery Low Buzzer10.2V
Battery Low Cut10.0V
Battery High Cut15.5V
Battery Charging Voltage by SPV14.5V
Battery Charging Current by SPV18A
Battery Charging Voltage by GRID14.2V
Battery Charging Current by GRID10A
Grid Low Cut Voltage ( IT Load Disable/Enable)120/175V
Grid High Cut Voltage ( IT Load Disable/Enable)280/255V
Inverter Nominal Output Voltage230VAC
Output Supply Phase1 phase, 3 wire
Output WaveformSine wave
Nominal Frequency50.0 HZ
Load Current9.1 A
Inverter Peak Efficiency>88%
ProtectionsOverload, Battery low, Battery high, Output low, Output high, Output Short Circuit, Overheat, Under Frequency, Over Frequency, Solar panel reverse
Display ParametersBattery Voltage, Charging Current, Discharging Current* Solar Voltage, Solar Current, Instantaneous Power, Grid Voltage, I/P Frequency Output Voltage, Output Load% O/P Frequency Grid, Inverter & SPV Charger Status
SwitchesReset for System ON/OFF, up, Down, Back, Enter (for LCD Configuration)
IndicationsSystem ON, Inv. ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under frequency, Over frequency, (IT Mode, Grid Charging, NLSD, Boost Charging, DG Mode)Enable/Disable*
Max Relative Humidity @25*C (non condensing)95%
Weight39KG
Dimension (L X W X H)457 X 254 X 431 mm
MRP ( Inclusive of all Taxes )
Discounted  Price ( Inclusive of all Taxes )

5KVA 48V Gamma PCU

DescriptionParticulars
Solar PCU Capacity5KVA 48V
Input Voltage Range (min-max)80-230 VDC
Maximum PV Power Recommended5KW
Types of ChargerPWM with MPPT
Charge Controller Peak Efficiency95%
Battery Low Buzzer10.2V
Battery Low Cut10.0V
Battery High Cut15.5V
Battery Charging Voltage by SPV14.5V
Battery Charging Current by SPV18A
Battery Charging Voltage by GRID14.2V
Battery Charging Current by GRID10A
Grid Low Cut Voltage ( IT Load Disable/Enable)120/175V
Grid High Cut Voltage ( IT Load Disable/Enable)280/255V
Inverter Nominal Output Voltage230VAC
Output Supply Phase1 phase, 3 wire
Output WaveformSine wave
Nominal Frequency50.0 HZ
Load Current15.2 A
Inverter Peak Efficiency>88%
ProtectionsOverload, Battery low, Battery high, Output low, Output high, Output Short Circuit, Overheat, Under Frequency, Over Frequency, Solar panel reverse
Display ParametersBattery Voltage, Charging Current, Discharging Current* Solar Voltage, Solar Current, Instantaneous Power, Grid Voltage, I/P Frequency Output Voltage, Output Load% O/P Frequency Grid, Inverter & SPV Charger Status
SwitchesReset for System ON/OFF, up, Down, Back, Enter (for LCD Configuration)
IndicationsSystem ON, Inv. ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under frequency, Over frequency, (IT Mode, Grid Charging, NLSD, Boost Charging, DG Mode)Enable/Disable*
Max Relative Humidity @25*C (non condensing)95%
Weight55KG
Dimension (L X W X H)457 X 254 X 431 mm
MRP ( Inclusive of all Taxes )
Discounted  Price ( Inclusive of all Taxes )

5KVA 96V Gamma PCU

DescriptionParticulars
Solar PCU Capacity5KVA 96V
Input Voltage Range (min-max)160-400  VDC
Maximum PV Power Recommended5KW
Types of ChargerPWM with MPPT
Charge Controller Peak Efficiency95%
Battery Low Buzzer10.2V
Battery Low Cut10.0V
Battery High Cut15.5V
Battery Charging Voltage by SPV14.5V
Battery Charging Current by SPV18A
Battery Charging Voltage by GRID14.2V
Battery Charging Current by GRID10A
Grid Low Cut Voltage ( IT Load Disable/Enable)120/175V
Grid High Cut Voltage ( IT Load Disable/Enable)280/255V
Inverter Nominal Output Voltage230VAC
Output Supply Phase1 phase, 3 wire
Output WaveformSine wave
Nominal Frequency50.0 HZ
Load Current15.2 A
Inverter Peak Efficiency>88%
ProtectionsOverload, Battery low, Battery high, Output low, Output high, Output Short Circuit, Overheat, Under Frequency, Over Frequency, Solar panel reverse
Display ParametersBattery Voltage, Charging Current, Discharging Current* Solar Voltage, Solar Current, Instantaneous Power, Grid Voltage, I/P Frequency Output Voltage, Output Load% O/P Frequency Grid, Inverter & SPV Charger Status
SwitchesReset for System ON/OFF, up, Down, Back, Enter (for LCD Configuration)
IndicationsSystem ON, Inv. ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under frequency, Over frequency, (IT Mode, Grid Charging, NLSD, Boost Charging, DG Mode)Enable/Disable*
Max Relative Humidity @25*C (non condensing)95%
Weight55KG
Dimension (L X W X H)457 X 254 X 431 mm
MRP ( Inclusive of all Taxes )
Discounted  Price ( Inclusive of all Taxes )

Unique Features

  • DSPic Based Pure Sine Wave Design.
  • Inbuilt rMPPT Charge Controller (30% more efficient).
  • Maximum Power Preference to Solar Energy.
  • Digital LCD (16X2) Display.
  • Priority Based Working Modes – Smart/PCU/Hybrid.
  • Reverse AC Voltage Protection.
  • Robust Design-20 years Product Life, 2-5 years of warranty.

Special Features

Solar Battery for Long Life

The solar battery fitted in gamma solar PCU feeds to it at a constant boost charging current until its voltage reaches 14.2V and the float current (which is very close to zero) then maintains this voltage above 13V. Thus reducing the float current (flowing for the longest period during the entire process) becomes zero, which ultimately results in greatly increased battery life and is fully charged simultaneously.

Extensive electronic protection

Gamma Solar PCU which ensures safety, it prevents reverse flow from battery to solar array, it provides load short circuit protection, it provides solar battery through DC fuse, overload protection, input low or high, output low / high or solar panel provides reverse protection.

Utilizes maximum power available from the solar panel

The gamma solar PCU senses the point of maximum power available in the solar panel and charges the battery with this maximum power. Therefore, at any given time the battery is charged with the maximum possible power.

LCD display

Finally, it has an LCD display for better user interface that displays battery voltage, current charge, current discharging current, output voltage, output frequency, output load percentage, input voltage, input frequency, solar voltage, solar current and solar energy

25

administrator

Tania

Comments (No Comments)

Comments (0):

Submit Your Comment

Your email address will not be published. Required fields are marked *