ALFA+ Solar PCU Inverter support in Dhaka

ALFA+ Solar PCU

We are introducing an advanced ALFA+ Solar PCU that is mainly used in Hospitals, schools, industries petrol pumps, banks and also in home. PCU means Power Conditioning Unit, is an integrated unit consists of grid charger, inverter, MPPT solar charger. ALFA+ Solar PCU Inverter support in Dhaka. Alfa + solar PCU continuously monitor battery and solar voltage as well as grid and output voltage with their current.

MPPT based solar charge controller extracts the maximum power from the solar panel whereby it increases the efficiency of the system. In Alfa+ Solar PCU MPPT charger has multi stage charging which maintains the battery charging voltage such that it increases the life of solar battery.

PCU means Power Conditioning Unit which uses solar power energy in first priority and grid (government electricity) in second priority to charge the solar batteries. Since usage of power from grid in Alfa+ Solar PCU is secondary, grid power is only used when solar energy isn’t present and battery voltage level reduces to 11.5V/Battery (Default 11.5V, Configurable). Grid power is also needed when solar power generation is less and battery voltage is reduced to 11.5V/Battery (Default 11.5V, Configurable).

ALFA+ PCU eMPPT Price

ALFA + Solar PCU
ALFA + Solar PCU
RatingMRP ( Inclusive of all Taxes )Discounted Price ( Inclusive of all Taxes )
Alfa+ 1KVA 24V
Alfa+ 2KVA 48V
Alfa+ 3KVA 48V
Alfa+ 5KVA 48V
Alfa+ 5KVA 96V
Alfa+ 7.5KVA 96V
Alfa+ 7.5KVA 120V
Alfa+ 10KVA 120V
Alfa+ 10KVA 180V
Alfa+ 15KVA 240V

Technical Specifications

The Alfa+ solar PCU is the most feature full solar PCU in rMPPT offline PCU (1Ph in 1Ph out) available in 1KVA to 15kVA.

1KVA 24V Alfa+ PCU

ParticularsDescription
Solar PCU Capacity1KVA 24V
Input Voltage Range (Min-Max)45-90 VDC
Maximum PV Power Recommended1KW
MPPT ControllerDSP
Type of ChargerMPPT
Efficiency95%
Battery Low BuzzerSmall Battery Cut +0.2 V
Battery Low Cut10-11.7 V
Battery High Cut (INV.)SPV Present-SPV CHG. REF +1V for 15Sec, SPV CHG. REF +1.5V for 2Sec
Battery High Cut (INV.)SPV Absent-SPV CHG. REF for 15Sec, SPV CHG. REF +0.2V for 2Sec
Battery Charging Voltage by SPV13.5-16 V
Battery Charging Current by SPV12-60 A
Battery Charging Voltage by Grid13.0-15.5 V
Battery Charging Current by Grid6-15 A
Grid Low Cut Voltage (IT Mode/Normal)NA/120-200 V
Grid High Cut Voltage (IT Mode/Normal)NA/245-280 V
Grid ChargingEnable/Disable
IT LoadEnable/Disable
Operating ModeSmart/PCU/Hybrid
Output Voltage Low170-190 V
Output Voltage High250-260 V
No Load Shut DownEnable/Disable
Input SourceGrid/Genset
Grid Disconnect (Solar Available) PCU/SMART (Battery)@14.5/Battery for 2minutes or 13.5/Battery-100% Current
Grid Reconnect (PCU Mode/Smart Mode) (Battery)11-12V
Temp. Compensation (Battery)@3mV/cell/°C ; 18mV/Battery/°C
Inverter Switching ElementMosfet
Inverter ControlPWM
Inverter Nominal Output Voltage220 VAC
Inverter Output Supply Phase1Phase, 3Wire
Inverter Output WaveformPure Sine Wave
Inverter Nominal Frequency50.0 Hz
Load Current4.5A
Voltage Regulation1%
Output Voltage Distortion with 100% Linear Load<3%
Peak Efficiency>82 %
CoolingTemp Controlled, Fan
ProtectionsOverload, Battery Low, Battery High, Output Low, Output High, Output Short Ckt., Overheat, Under Frequency, Over Frequency, Solar Panel Reverse
Display ParametersBattery Voltage, Charging Current, Discharging Current, Charging KWH, Discharging KWH, Solar Voltage, Solar Current, Instantaneous Power, Cumulative Power, Grid Voltage, Grid Current, Grid Frequency, Output Voltage, Output Current, Output Frequency NLSD En/Dn, IT Load En/Dn Grid Charger En/Dn, Operating Mode PCU/SMT/HYD
SwitchesReset for System ON/OFF, UP, DOWN, BACK, ENTER (for LCD Configuration)
IndicationsSystem ON, Inverter ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under Frequency, Over Frequency, NLSD, Fault
Degree of ProtectionIP21
Dimension (LxWxH)457X 254 X 457 mm
Weight (Approx)32KG
MRP ( Inclusive of all Taxes )
Discounted Price ( Inclusive of all Taxes )

2KVA 48V Alfa+ PCU

ParticularsDescription
Solar PCU Capacity2KVA 48V
Input Voltage Range (Min-Max)80-230 VDC
Maximum PV Power Recommended2KW
MPPT ControllerDSP
Type of ChargerMPPT
Efficiency95%
Battery Low BuzzerMinimum Battery Cut +0.2 V
Battery Low Cut10-11.7 V
Battery High Cut (INV.)SPV Present-SPV CHG. REF +1V for 15Sec, SPV CHG. REF +1.5V for 2Sec
Battery High Cut (INV.)SPV Absent-SPV CHG. REF for 15Sec, SPV CHG. REF +0.2V for 2Sec
Battery Charging Voltage by SPV13.5-16 V
Battery Charging Current by SPV12-60 A
Battery Charging Voltage by Grid13.0-15.5 V
Battery Charging Current by Grid6-15 A
Grid Low Cut Voltage (IT Mode/Normal)NA/120-200 V
Grid High Cut Voltage (IT Mode/Normal)NA/245-280 V
Grid ChargingEnable/Disable
IT LoadEnable/Disable
Operating ModeSmart/PCU/Hybrid
Output Voltage Low170-190 V
Output Voltage High250-260 V
No Load Shut DownEnable/Disable
Input SourceGrid/Genset
Grid Disconnect (Solar Available) PCU/SMART (Battery)@14.5/Battery for 2minutes or 13.5/Battery-100% Current
Grid Reconnect (PCU Mode/Smart Mode) (Battery)11-12V
Temp. Compensation (Battery)@3mV/cell/°C ; 18mV/Battery/°C
Inverter Switching ElementMosfet
Inverter ControlPWM
Inverter Nominal Output Voltage220 VAC
Inverter Output Supply Phase1Phase, 3Wire
Inverter Output WaveformPure Sine Wave
Inverter Nominal Frequency50.0 Hz
Load Current9 A
Voltage Regulation1%
Output Voltage Distortion with 100% Linear Load<3%
Peak Efficiency>88 %
CoolingTemp Controlled, Fan
ProtectionsOverload, Battery Low, Battery High, Output Low, Output High, Output Short Ckt., Overheat, Under Frequency, Over Frequency, Solar Panel Reverse
Display ParametersBattery Voltage, Charging Current, Discharging Current, Charging KWH, Discharging KWH, Solar Voltage, Solar Current, Instantaneous Power, Cumulative Power, Grid Voltage, Grid Current, Grid Frequency, Output Voltage, Output Current, Output Frequency NLSD En/Dn, IT Load En/Dn Grid Charger En/Dn, Operating Mode PCU/SMT/HYD
SwitchesReset for System ON/OFF, UP, DOWN, BACK, ENTER (for LCD Configuration)
IndicationsSystem ON, Inverter ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under Frequency, Over Frequency, NLSD, Fault
Degree of ProtectionIP21
Dimension (LxWxH)457 X 254 X 457 mm
Weight (Approx)40KG
MRP ( Inclusive of all Taxes )
Discounted Price ( Inclusive of all Taxes )

5KVA 48V Alfa+ PCU

ParticularsDescription
Solar PCU Capacity5KVA 48V
Input Voltage Range (Min-Max)80-230 VDC
Maximum PV Power Recommended5KW
MPPT ControllerDSP
Type of ChargerMPPT
Efficiency95%
Battery Low BuzzerLow Cut +0.2 V
Battery Low Cut10-11.7 V
Battery High Cut (INV.)SPV Present-SPV CHG. REF +1V for 15Sec, SPV CHG. REF +1.5V for 2Sec
Battery High Cut (INV.)SPV Absent-SPV CHG. REF for 15Sec, SPV CHG. REF +0.2V for 2Sec
Battery Charging Voltage by SPV13.5-16 V
Battery Charging Current by SPV12-60 A
Battery Charging Voltage by Grid13.0-15.5 V
Battery Charging Current by Grid6-15 A
Grid Low Cut Voltage (IT Mode/Normal)NA/120-200 V
Grid High Cut Voltage (IT Mode/Normal)NA/245-280 V
Grid ChargingEnable/Disable
IT LoadEnable/Disable
Operating ModeSmart/PCU/Hybrid
Output Voltage Low170-190 V
Output Voltage High250-260 V
No Load Shut DownEnable/Disable
Input SourceGrid/Genset
Grid Disconnect (Solar Available) PCU/SMART (Battery)@14.5/Battery for 2minutes or 13.5/Battery-100% Current
Grid Reconnect (PCU Mode/Smart Mode) (Battery)11-12V
Temp. Compensation (Battery)@3mV/cell/°C ; 18mV/Battery/°C
Inverter Switching ElementMosfet
Inverter ControlPWM
Inverter Nominal Output Voltage220 VAC
Inverter Output Supply Phase1Phase, 3Wire
Inverter Output WaveformPure Sine Wave
Inverter Nominal Frequency50.0 Hz
Load Current18 A
Voltage Regulation1%
Output Voltage Distortion with 100% Linear Load<3%
Peak Efficiency>88 %
CoolingTemp Controlled, Fan
ProtectionsOverload, Battery Low, Battery High, Output Low, Output High, Output Short Ckt., Overheat, Under Frequency, Over Frequency, Solar Panel Reverse
Display ParametersBattery Voltage, Charging Current, Discharging Current, Charging KWH, Discharging KWH, Solar Voltage, Solar Current, Instantaneous Power, Cumulative Power, Grid Voltage, Grid Current, Grid Frequency, Output Voltage, Output Current, Output Frequency NLSD En/Dn, IT Load En/Dn Grid Charger En/Dn, Operating Mode PCU/SMT/HYD
SwitchesReset for System ON/OFF, UP, DOWN, BACK, ENTER (for LCD Configuration)
IndicationsSystem ON, Inverter ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under Frequency, Over Frequency, NLSD, Fault
Degree of ProtectionIP21
Dimension (LxWxH)457 X 254 X 457 mm
Weight (Approx)50KG
MRP ( Inclusive of all Taxes )
Discounted Price ( Inclusive of all Taxes )

10KVA 180V Alfa+ PCU

ParticularsDescription
Solar PCU Capacity10KVA 180V
Input Voltage Range (Min-Max)80-230 VDC
Maximum PV Power Recommended10KW
MPPT ControllerDSP
Type of ChargerMPPT
Efficiency95%
Battery Low BuzzerLow Voltage Battery Cut +0.2 V
Battery Low Cut10-11.7 V
Battery High Cut (INV.)SPV Present-SPV CHG. REF +1V for 15Sec, SPV CHG. REF +1.5V for 2Sec
Battery High Cut (INV.)SPV Absent-SPV CHG. REF for 15Sec, SPV CHG. REF +0.2V for 2Sec
Battery Charging Voltage by SPV13.5-16 V
Battery Charging Current by SPV12-60 A
Battery Charging Voltage by Grid13.0-15.5 V
Battery Charging Current by Grid6-15 A
Grid Low Cut Voltage (IT Mode/Normal)NA/120-200 V
Grid High Cut Voltage (IT Mode/Normal)NA/245-280 V
Grid ChargingEnable/Disable
IT LoadEnable/Disable
Operating ModeSmart/PCU/Hybrid
Output Voltage Low170-190 V
Output Voltage High250-260 V
No Load Shut DownEnable/Disable
Input SourceGrid/Genset
Grid Disconnect (Solar Available) PCU/SMART (Battery)@14.5/Battery for 2minutes or 13.5/Battery-100% Current
Grid Reconnect (PCU Mode/Smart Mode) (Battery)11-12V
Temp. Compensation (Battery)@3mV/cell/°C ; 18mV/Battery/°C
Inverter Switching ElementMosfet
Inverter ControlPWM
Inverter Nominal Output Voltage220 VAC
Inverter Output Supply Phase1Phase, 3Wire
Inverter Output WaveformPure Sine Wave
Inverter Nominal Frequency50.0 Hz
Load Current36 A
Voltage Regulation1%
Output Voltage Distortion with 100% Linear Load<3%
Peak Efficiency>88 %
CoolingTemp Controlled, Fan
ProtectionsOverload, Battery Low, Battery High, Output Low, Output High, Output Short Ckt., Overheat, Under Frequency, Over Frequency, Solar Panel Reverse
Display ParametersBattery Voltage, Charging Current, Discharging Current, Charging KWH, Discharging KWH, Solar Voltage, Solar Current, Instantaneous Power, Cumulative Power, Grid Voltage, Grid Current, Grid Frequency, Output Voltage, Output Current, Output Frequency NLSD En/Dn, IT Load En/Dn Grid Charger En/Dn, Operating Mode PCU/SMT/HYD
SwitchesReset for System ON/OFF, UP, DOWN, BACK, ENTER (for LCD Configuration)
IndicationsSystem ON, Inverter ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under Frequency, Over Frequency, NLSD, Fault
Degree of ProtectionIP21
Dimension (LxWxH)609 X 330 X 660 mm
Weight (Approx)103 KG
MRP ( Inclusive of all Taxes )
Discounted Price ( Inclusive of all Taxes )

15KVA 240V Alfa+ PCU

ParticularsDescription
Solar PCU Capacity15KVA 240V
Input Voltage Range (Min-Max)400-750 VDC
Maximum PV Power Recommended15KW
MPPT ControllerDSP
Type of ChargerMPPT
Efficiency95%
Battery Low BuzzerLow Volt Battery Cut +0.2 V
Battery Low Cut10-11.7 V
Battery High Cut (INV.)SPV Present-SPV CHG. REF +1V for 15Sec, SPV CHG. REF +1.5V for 2Sec
Battery High Cut (INV.)SPV Absent-SPV CHG. REF for 15Sec, SPV CHG. REF +0.2V for 2Sec
Battery Charging Voltage by SPV13.5-16 V
Battery Charging Current by SPV12-60 A
Battery Charging Voltage by Grid13.0-15.5 V
Battery Charging Current by Grid6-15 A
Grid Low Cut Voltage (IT Mode/Normal)NA/120-200 V
Grid High Cut Voltage (IT Mode/Normal)NA/245-280 V
Grid ChargingEnable/Disable
IT LoadEnable/Disable
Operating ModeSmart/PCU/Hybrid
Output Voltage Low170-190 V
Output Voltage High250-260 V
No Load Shut DownEnable/Disable
Input SourceGrid/Genset
Grid Disconnect (Solar Available) PCU/SMART (Battery)@14.5/Battery for 2minutes or 13.5/Battery-100% Current
Grid Reconnect (PCU Mode/Smart Mode) (Battery)11-12V
Temp. Compensation (Battery)@3mV/cell/°C ; 18mV/Battery/°C
Inverter Switching ElementMosfet
Inverter ControlPWM
Inverter Nominal Output Voltage220 VAC
Inverter Output Supply Phase1Phase, 3Wire
Inverter Output WaveformPure Sine Wave
Inverter Nominal Frequency50.0 Hz
Load Current54 A
Voltage Regulation1%
Output Voltage Distortion with 100% Linear Load<3%
Peak Efficiency>88 %
CoolingTemp Controlled, Fan
ProtectionsOverload, Battery Low, Battery High, Output Low, Output High, Output Short Ckt., Overheat, Under Frequency, Over Frequency, Solar Panel Reverse
Display ParametersBattery Voltage, Charging Current, Discharging Current, Charging KWH, Discharging KWH, Solar Voltage, Solar Current, Instantaneous Power, Cumulative Power, Grid Voltage, Grid Current, Grid Frequency, Output Voltage, Output Current, Output Frequency NLSD En/Dn, IT Load En/Dn Grid Charger En/Dn, Operating Mode PCU/SMT/HYD
SwitchesReset for System ON/OFF, UP, DOWN, BACK, ENTER (for LCD Configuration)
IndicationsSystem ON, Inverter ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under Frequency, Over Frequency, NLSD, Fault
Degree of ProtectionIP21
Dimension (LxWxH)609 X 330 X 660 mm
Weight (Approx)120 KG
MRP ( Inclusive of all Taxes )
Discounted Price ( Inclusive of all Taxes )

Unique Features

Battery Selection Mode

In UTL’s Alfa+ Solar PCU you have a great feature that is battery selection mode by this we can select any type of battery as per requirement i.e. flat plate/tubular/SMF/Lead acid Battery and can set charging voltage and charging current as per requirement.

Operating Mode Selection

PCU Mode – Priority   Solar →Battery → Grid.

Smart Mode -Priority   Solar → Grid → Battery.

Hybrid Mode – Priority for load   Grid →Solar → Battery.

Priority for battery charging    Solar Energy → Grid.

LCD Display with Energy Meter and Data Logging (optional)

UTL Alfa+ Solar PCU is also available with LCD display. This is an optional feature that can be availed by the customer for better user interface. When the customer opts for this feature, an energy meter and data logging facilities are also provided to the customer, which help the user to access information about the present and past status of the PCU functionality.

Pure Sine Wave

The output of the UTL’s Alfa+ PCU is pure sine wave and it operates your appliances friendly.

User configurable by LCD

User friendly calibration settings:-

You can change the below settings of Alfa+ Solar PCU by itself like,

Configurable Grid Reconnect Setting.

Battery Low cut Setting (Configurable).

Grid low cut/High cut setting.

User friendly operational settings

No load shut down – Enable/Disable.

Grid charging – Enable/Disable.

IT Load – Enable/Disable.

Advanced features

  • DSPic Based Pure Sine Wave Design.
  • Inbuilt rMPPT Charge Controller.
  • Maximum Preference to Solar Energy.
  • USB Based Communication.
  • 30 Days Data Logs Inbuilt
  • AC and DC Energy Meter Inbuilt.
  • GSM/GPRS Based Remote Monitoring and controlling.
  • Robust Design for 20 years product life.
  • 2 years to 5 years of warranty.
  • Reverse AC Voltage Protection.
  • User friendly and easily accessible LCD Display with all AC & DC Parameter Configurable by Display Switches and Digital LCD (20X4).
  • User Friendly Control: – Output Voltage, Charging Voltage – SPV/ Grid, Charging Current – SPV/Grid, Grid Reconnect, Battery Low.
  • Priority based working modes – Smart/PCU/Hybrid (for saving energy and money).
  • NLSD, Alfa+ Solar PCU Grid Charging, IT Load – Enable/Disable by LCD.

FAQs about Alfa+

Q. Is it available in 3kw 24v system?

Answer: Yes. For more information go to UTL contact us.

Q. Can it work without battery?

Answer: No, it you need solar batteries to run Alfa plus Solar Inverter (PCU).

Q. How many years Guarantee?

Answer: There is onsite warranty of Alfa+ Solar Inverter by UTL Solar.

Q. Is it possible to use two solar battery of 150Ah 48v?

Answer: Yes.

Q. How much power of load 5KVA Alfa+ Solar PCU can support?

Answer: 5KVA Alfa+ Solar PCU can run approx. 4150 watts.

Q. What types of controller used and what is the ampere of controller maximum voc?

Answer: In Alfa+, MPPT solar change controller is used with 80-230V and 100Amp maximum VOC.

Q. This is on-grid or off grid inverter? Will Alfa+ solar inverter work for both?

Answer: This is only off grid solar inverter. If you need UTL hybrid solar inverter that works both likes on grid and off grid solar inverter than contact us.